| 8.000.6089 | Automated sample measurement in Karl Fischer titration
|
| 8.000.6088 | Sensitivity meets selectivity – the new amperometric detector |
| 8.000.6087 | Determination of hexavalent chromium in drinking water according to a U.S. EPA Method |
| 8.000.6086 | Semi-continuous determination of anions, cations, and heavy metals in aerosols using PILS-IC-VA |
| 8.000.6085 | Monitoring of iodine- and gadolinium-containing contrast media in water treatment plants |
| 8.000.6084 | Spectroelectrochemical analysis of a N-aryl-D2-pyrazoline derivative |
| 8.000.6083 | The numerous sample conditioning and sample preparation options offered by an atline analysis system |
| 8.000.6082 | Monitoring of a complete process line for the phosphatizing of metal surfaces using an atline analysis system |
| 8.000.6081 | Determination of the oxidative stability of biodiesel (fatty acid methyl esters, FAME) |
| 8.000.6080 | Thermometric titration – the missing piece of the titration puzzle |
| 8.000.6079 | Automated Karl Fischer titration for liquid samples using edible oils as an example |
| 8.000.6078 | Water determination in pharmaceuticals using an automated Karl Fischer Oven Technique |
| 8.000.6077 | Determining the water content in biodiesel by Karl Fischer titration as per EN ISO 12937 |
| 8.000.6076 | Sequential suppression for conductivity detection in ion chromatography |
| 8.000.6075 | Determination of pyrophosphate, trimetaphosphate, tripolyphosphate, and standard ions in detergents or fertilizers using IC with a high-capacity suppressor |
| 8.000.6074 | Influence of pH, temperature, and molybdate concentration on the performance of the triiodide method for the trace-level determination of bromate (EPA 326) |
| 8.000.6073 | Determination of anions in concentrated nitric acid by ion chromatography: the influence of temperature on column selectivity |
| 8.000.6072 | Trace-level determination of cations in the secondary circuit of a PWR-type nuclear power plant using ion chromatography after inline sample preparation |
| 8.000.6071 | Trace-level determination of anions in the primary circuit of a PWR-type nuclear power plant using ion chromatography after inline sample preparation |
| 8.000.6070 | Comprehensive, fully automated water analysis |
| 8.000.6069 | Determination of the oxidation stability of fat-containing solid foodstuffs |
| 8.000.6068 | Determination of the stabilizers antimony, bismuth, and iodate in electroless nickel baths as replacements for lead |
| 8.000.6067 | Fully automatic determination of sodium in food samples |
| 8.000.6066 | Determination of the total acid number (TAN) using thermometric titration |
| 8.000.6065 | Automated ion chromatographic determinations over six orders of magnitude |